AquaBoost II
Input Power* — 208-230V ±15%, single phase (controller only)
Output Power — Up to 230V three phase (based on input voltage). Motor rated for 208-230V, ±10%.
Maximum Output Current — 4.2 amps – 1AB2 (1 HP) — 6.9 amps – 2AB2 (2 HP)
Input Controls — Up and down buttons to set pressure.
Signal Lights — Power on, pump running, inverter, stopped, pump stopped, standby, faults/errors.
Electrical Efficiency — Over 95% at full load
Protection Against — Short circuit, under voltage, overload, motor temperature, dead heading, run out, suction,
loss, sensor fault, bound pump, over voltage, static discharge. Note: Suction loss/run out is set for minimum 10 psi at discharge!
Ambient Temperature — 34º F to 104º F
Maximum Humidity — 95% at 104º F, non-condensing
Air Pollution — Avoid mounting in areas with excessive dust, acids, corrosives and salts.
Approvals —
Controller Enclosure — Outdoor, NEMA 3R, IP 43(Rain-tight)
Mounting — Wall mount with mounting hardware.
Cooling — Convection with cast aluminum heat sink.
— 3 HP, 5 HP with temperature fan
Transducer — 0.5 - 4.5 VDC with 5 VDC power supply, 100 psi range, 10-foot 3-wire shielded cable.
Input Wire — 5 feet of 14, 10 or 8 gauge cable. Depending on size, cable is pre-wired to controller and motor conduit box.
Output Wire — 10 feet of 14 gauge cable. Cable is prewired to controller and pump motor (when provided).
*Low input voltage may affect motor operation.
INPUT AND OUTPUT POWER (VOLTAGE AND PHASE)
• All 1AB2 and 2AB2 require single-phase input power • All controllers output three-phase, 230 Volt power
o All will work on 1Ø, 208-230V input power • All pumps are equipped with three-phase motors
o Some 1AB2’s will work on 1Ø, 115V input power.
*1AB2LB1035 Goulds Aqua Boost
• 1 HP controller • Wall mount set
• LB stainless steel jet pump
• Transducer • Discharge tee • V6P tank, pressure gauge
• Controller is pre-wired to the pump. Flows to 15 GPM.
2AB21MC1F2B2 Goulds Aqua Boost
• 2 HP controller • Wall mount set • 208-230 V input
• MCC cast iron / stainless steel pump
• Transducer • V6P (2 gallon) tank and pressure gauge
• Controller is pre-wired. Flows to 27 GPM
2AB21MC1G2A2 Goulds Aqua Boost
• 2 HP controller • Wall mount kit • 208-230 V input
• MCC cast iron / stainless steel pump
• Transducer • V6P (2 gallon) tank and pressure gauge
• Controller is pre-wired. Flows to 32 GPM.
*1AB21HM1E2D0 Goulds Aqua Boost
• 1 HP controller • Wall mount kit • 208-230 V input
• HMS stainless steel pump • Transducer
• V6P (2 gallon) tank and discharge pipe tee
• Controller is pre-wired. Flows to 20 GPM.
*1AB22HM1E2D0 Goulds Aqua Boost
• 1 HP controller • Wall mount kit • 208-230 V input
• HMS stainless steel pump • Transducer
• V6P (2 gallon) tank, pressure gauge and discharge pipe tee
• Controller is pre-wired. Flows to 30 GPM.
2AB22HM1F2E0 Goulds Aqua Boost
• 2 HP controller • Wall mount kit • 208-230 V input
• HMS stainless steel pump • Transducer
• V6P (2 gallon) tank, pressure gauge and discharge pipe tee
• Controller is pre-wired. Flows to 30 GPM.
3AB2LCB1H2D0 Goulds Aqua Boost
• 3 HP controller • Wall mount kit • 208-230 V input
• LCB stainless steel pump • Transducer
• V6P (2 gallon) tank, pressure gauge and discharge pipe tee
• Controller is pre-wired. Flows to 50 GPM.
2AB22MC1G2D2 Goulds Aqua Boost
• 2 HP controller • Wall mount kit • 208-230 V input
• MCC cast iron/stainless steel impeller pump
• Pressure transducer
• V6P (2 gallon) tank, pressure gauge, 1¼" bronze discharge tank tee
• Controller and motor are pre-wired. Flows to 80 GPM.
**5AB22MC1J2K2 Gould Aqua Boost
• 5 HP controller • Wall mount • 208-230 V input
• MCC cast iron/stainless impeller pump
• Pressure transducer
• Pressure gauge, 1¼" bronze tank tee
• Controller and motor are pre-wired. Flows to 100 GPM.
**5AB2LCC1J2D0 Goulds Aqua Boost
• 5 HP controller • Wall mount • 208-230 V input
• LCC stainless steel pump • Pressure transducer
• Pressure gauge, 1¼" bronze tank tee
• Controller and motor are pre-wired. Flows to 70 GPM.
* 1 HP available in 115 volt models.
** Tank not included